Clean surfaces & maintain equipment
For hard-surface cleaning, floor care, polishing and composite cleaning tools. Confirm the substrate, pressure, wet-use conditions and acceptable wear before selecting a grade.
View cleaning productsStart with the application, then confirm format, density, surface and processing route. This center connects Kangerna’s cleaning, acoustic, thermal and custom-conversion options so project teams can define the right sample before sourcing.
Begin with the primary function of the part. A grade that performs well in one application is not automatically suitable for another, so the selection path should follow the job, environment and finished format.
For hard-surface cleaning, floor care, polishing and composite cleaning tools. Confirm the substrate, pressure, wet-use conditions and acceptable wear before selecting a grade.
View cleaning productsFor wall, ceiling and decorative acoustic formats. Match panel construction, thickness, mounting method, edge detail and finish to the acoustic and interior requirement.
View acoustic productsFor thermal boards, pipe insulation, foil-laminated formats and projects with hydrophobic or low-formaldehyde requirements. Verify the exact model and its published test data.
View thermal productsFor CNC shapes, compression, adhesive backing, foil lamination, fabric or leather wrapping and composite cleaning tools. Selection depends on the drawing and approved reference.
View custom optionsUse these families to shortlist a starting point. Product names help narrow the route, but the exact model, grade and construction still need to be confirmed against the drawing, sample and current technical information.
Cleaning & surface care
For hard-surface cleaning, floor care, polishing, mop systems and composite cleaning tools. Select by substrate, pressure, wet or dry use and the acceptable wear pattern.
Start with: surface, pressure and wear requirement. Confirm: grade, density, shape and packaging on sample.
Acoustic & interior
For wall, ceiling, decorative and fabricated acoustic formats. Compare the panel build, thickness, edge, mounting method and finish together rather than by color alone.
Start with: acoustic target and mounting detail. Confirm: model-specific NRC or absorption data, thickness, finish and fire documentation.
Thermal & industrial
For thermal boards, pipe insulation, foil-laminated formats and projects with hydrophobic, low-formaldehyde or higher-density requirements. Verify the exact grade and its conditions of use.
Start with: operating temperature, moisture and fire requirement. Confirm: grade-specific thermal, flame and environmental data.
Specialty & conversion
Use this route when the foam becomes a component: CNC-cut, compressed, laminated, wrapped, adhesive-backed or combined with another material. Review the drawing and approved reference before production.
Start with: CAD drawing, target fit and mating material. Confirm: machinability, tolerances, adhesive or laminate, packing and approval sample.
The matrix gives a practical starting point, not a final specification. Move from the requirement to a product route, then use current technical data and a sample to validate the exact grade and format.
| Project requirement | Start with | Review next | Confirm on sample or TDS |
|---|---|---|---|
| Hard-surface stain removal | Magic sponge eraser formats | Shape, compression, wet strength and wear | Substrate compatibility, pressure, cleaning method and acceptable surface change |
| Acoustic wall or ceiling panel | Sound-absorbing panels or fabricated foam cores | Thickness, edge detail, facing and mounting | Model-specific acoustic data, fire documentation and finish |
| Thermal board or equipment insulation | Thermal board, roll or pipe format | Density, thickness, foil facing and service temperature | Thermal conductivity, temperature limits and installation conditions |
| Dimensional stability during converting | High-density foam, 12–80 kg/m³ | Density target, thickness range and cutting method | Machining quality, tolerance, dust control and final fit |
| Parts exposed to moisture | Hydrophobic melamine foam | Water exposure mode, drainage and cleaning cycle | Grade-specific hydrophobic performance and durability after repeated exposure |
| Lower-formaldehyde material preference | Low-formaldehyde melamine foam | Test method, target limit and component materials | Current report for the selected grade and the full finished assembly |
| CNC shape, lamination or wrapped finish | Specialty and conversion route | Drawing, tolerance, adhesive, substrate and edge quality | Approved drawing or reference sample, fit and handling requirements |
| A specific color or surface appearance | White, grey or pink foam formats | Base grade, color consistency and visible surface | Color target, lighting condition, batch expectation and finish |
Product selection is a combination of material and format. Changing one variable can change handling, fit, acoustic behavior, thermal performance or the way the part is installed.
Density affects handling, compression behavior, machining and the feel of the finished part. Kangerna publishes grades such as 8.0 ± 1.0 kg/m³ and 8.7 ± 1.5 kg/m³, while selected high-density products cover 12–80 kg/m³. Specify density with the exact model and test method.
White, grey and pink are appearance choices and can differ by product line. Color alone does not establish density, acoustic performance, flame behavior or suitability for an application. Confirm the base grade and color together.
Regular, semi-grid and other visible structures can influence appearance, cleaning action and the way the surface accepts a laminate or coating. Match the structure to the visual and functional requirement, then validate it in the intended process.
Sheet, block, roll, pipe and machined formats are not interchangeable. Some standard sheet options reach 2500 × 1250 mm, while selected high-density products are listed from 2–50 mm. Confirm the target dimensions and tolerances for the exact item.
Adhesive, aluminum foil, fabric, leather and composite constructions introduce extra interfaces. State the mating substrate, surface energy, service environment and installation method so the adhesive or laminate can be reviewed with the foam.
Flame and temperature information is grade- and construction-specific. Some product pages report GB8624 B1, UL94 V0 or HF-1, and some models list service temperatures from −200°C to +220°C or +240°C. Do not generalize these values to another product.
A good selection brief reduces avoidable sample cycles. It also separates a promising material direction from a construction that has already been tested for the intended use.
The project has enough definition to review a material route, conversion method and approval sample.
These conditions can still be discussed, but they should not be approved from a generic product description.
A concise brief is more useful than a broad request for “the best foam.” The details below let the team compare the material and the finished component at the same time.
Include what is known and mark what is still open. Missing information can be handled as a review point rather than assumed.
Kangerna’s quality process uses incoming, in-process, final and outgoing checkpoints. The applicable inspection items are tied to the product and approved specification.
Use these answers to frame the first technical review. The exact product data, current test documents and approved sample remain the deciding references.
Color is an appearance choice, not a performance grade. White, grey and pink melamine foam can differ in base grade, density, pore structure and available format. Ask for the exact model and current TDS, then compare the required cleaning, acoustic or thermal properties and approve the color on the intended material sample.
Start with the Sound-Absorbing & Flame-Retardant Panels group when the finished product is a wall or ceiling panel, or with the relevant foam sheet or block when the panel will be fabricated. Acoustic results depend on thickness, density, air gap, mounting and facing. Treat NRC figures as model-specific and confirm the complete build before specifying performance.
Choose compressed melamine foam when the process or handling route requires a reduced initial thickness and the application can accept its recovery behavior. Consider high-density melamine foam when the drawing calls for greater dimensional support, machining control or a specific density within the 12–80 kg/m³ range. Neither option should be selected from density or compression alone; confirm the target, sample and test method.
Yes. Kangerna can review CNC shaping and engraving, compression, PU or scouring-pad composites, adhesive backing, aluminum-foil lamination and fabric or leather wrapping. Send the drawing or reference, mating substrate, adhesive or finish requirement and target quantity. Feasibility and tolerances are confirmed through the technical review and approval sample, not from the product name alone.
Send the application, substrate or mating material, target dimensions and tolerances, drawing if available, preferred density or grade, thickness, color, surface or adhesive requirement, operating environment, relevant test standard, sample quantity and packaging expectation. This information lets Kangerna review the material and conversion route and define the sample to evaluate.
Share the application, drawing or target performance. Kangerna can review the material and conversion route and help define the next sample.